Problem 105-1
Source:
Adapted from Example 3-2 - page 177 - CHAPMAN, Sthephen J. - Book:
Fundamentos de Máquinas Elétricas - 5ª Edição - Ed. McGraw-Hill - 2013.
Let's assume a simple two-pole generator. The magnetic induction field of the rotor, BR, is worth
0.2 T and the mechanical rotation speed of the shaft is 3,600 rpm. The diameter of the machine stator
is 0.5 m, the length of its coil is 0.3 m and there are 15 turns per coil. The machine is
connected to Y. Determine:
a) What are the three phase voltages of the generator as a function of time?
b) What is the effective phase voltage of this generator??
c) What is the effective voltage at the terminals of this generator??
Problem 105-2
Source: Adapted from Example 7-7 - page 432 - GURU, Bagh S. & HIZIROGLU, Huseyin R. Book:
Electric Machinery and Transformers - 3ª Edição - Ed. Oxford University Press - 2001.
A three-phase 9 kVA synchronous generator in a wye configuration operates at 220 V, 60 Hz at 1,200 rpm and has a
field resistance of 4.5 Ω. The armature winding impedance is 0.3 + j 5 Ω / phase.
When the generator operates at rated power with PF = 0.8 lagging, the field current is 5 A. The rotational losses are 500 W.
Determine:
Problem 105-3
Source: Adapted from Example 6.3 - page 307 - SEN, P. C. - Book:
Principles of Electric Machines and Power Eletronics - 3ª Edição - Ed. Wilei - 2014.
A three-phase 5 kVA synchronous generator in a wye configuration operates at 208 V, 60 Hz, and has
negligible armature resistance.
The armature winding reactance is 8 Ω / phase.
a)Determine the voltage EMF and the power angle of the generator when it operates at rated power with PF = 0.8 lagging.
b) If the field current is increased by 20%, without changing the prime mover power, find the
armature current, power factor, and reactive power in the machine.
c) With the field current from item a, the prime mover power is increased slowly. What is the
stability limit? What are the corresponding values of the armature current, power factor, and
reactive power for maximum power under this condition.
Problem 105-4
Source: Adapted from Example 6.16 - page 557 - SHADEV, S. K. - Book:
Electrical Machines - 1ª Edição - Ed. Cambridge University Press - 2018.
A single-phase 60 kVA synchronous generator operates at 220 V, 60 Hz, and has negligible armature resistance.
The armature winding reactance is 0.07 Ω.
When the alternator supplies rated current to a load with PF = 0.7 lagging, find:
Problem 105-5
Source: Adapted from Example 6.19 - page 559 - SHADEV, S. K. - Book:
Electrical Machines - 1ª Edição - Ed. Cambridge University Press - 2018.
A three-phase synchronous generator connected in a star-type connection has an
armature resistance of 0.1 Ω / phase. When open-circuited, the line voltage is 173.3 V.
When short-circuited, the current is 200 A.
The goal is to maintain a line voltage of 400 V when the generator supplies a load that consumes 100 A.
Find
a) the induced armature voltage, EA, when FP = 0.8 lagging;
b) the induced armature voltage, EA, when FP = 0.75 leading.
Problem 105-6
Source: Problem created by the website author.
A three-phase 200 kVA synchronous generator, connected in a wye, has an open-circuit line voltage of 2,300 V.
The average DC armature resistance measured between the two lines is R = 0.4 Ω.
When short-circuited, the generator draws a current of 80 A.
Find:
a) the synchronous reactance per phase of the generator;
Problem 105-7
Source: Problem created by the website author.
A three-phase, wye-connected, 25 kVA, 60 Hz synchronous generator, operating
with a line terminal voltage of 440 V, has an
armature resistance of 0.4 Ω / phase and a synchronous reactance of 1.9 Ω / phase.
Assume the generator is operating at rated load and PF = 0.85 lagging.
Find:
a) the nominal current;
b) the real power delivered by the generator to the load;
Problem 105-8
Source: Adapted from Example 5.14 - page 471 - BHATTACHARYA, S. K. - Book:
Electrical Machines - 4ª Edição - Ed. McGrawHill Education - 2014.
A three-phase, star-connected, 1,500 kVA, 60 Hz synchronous generator, operating
at a line terminal voltage of 6,000 V, has an
armature resistance of 0.4 Ω / phase and a synchronous reactance of 6 Ω / phase.
a) calculate the induced voltage for a nominal load with FP = 0.80 lagging;
b) keeping the excitation constant, find the terminal voltage for a nominal load
with FP = 0.80 leading ;